() 해외배송 가능
판매가 | 문의 |
---|---|
소비자가 | 0원 |
적립금 |
|
제휴 적립금 | 네이버 마일리지 적립 |
무이자할부 | |
제조사 | CHECK-LINE |
원산지 | |
상품코드 | P0000BXI |
수량 | |
국내/해외배송 | |
SNS 상품홍보 | |
싸이월드 스크랩 |
|
| |
Data-Logging Ultrasonic Coating & Wall Thickness Gauge 2 Versions: TI-CMXDLP - Black & white model TI-CMXDLP-C - Color model Five user-selected operating modes are included: Coating On: Measures wall thickness using Pulse-Echo. It separately displays wall & coating thickness. Coating Off: Measures wall thickness using Pulse-Echo. It displays wall thickness only. Temperature Compensated: Measures wall thickness using Pulse-Echo and automatically adjusts calibration to compensate for changes in material temperature. Thru-Coat: Measures wall thickness only using Echo-Echo. (coating is NOT included) Coating Only Mode (CT): (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.013 to 2.540 mm). Range will vary slightly depending on the coating. Special Features of TI-CMXDLP Data-Logger - Built-in memory with RS-232 output for transferring data to a Printer or PC - Includes Datacomm Data Transfer & Analysis Software and RS-232 Cable, FREE - Data Files can be user-set for a "grid type" structure where data is formatted in Rows & Columns or a "sequential" file where all data appears in a single column - Each "grid type" File can be set for up to 999 rows by 52 columns - Each "sequential" File can be set for up to 512 rows by 1 column - Each File can be set for "data only" or as "data plus B-scan Graphic". Memory Capacity is over 225,000 data values or over 16,000 data values with B-scan - Auto probe recognition with Auto Zero or Manual Zero. - Wide variety of dual-element probes can be used for nearly any application. - Bar graph with user-set start end values providing highest resolution around the target thickness value. - Differential Mode allows user to set a "target thickness value" and display will show the DIFFERENCE between actual and target thickness as a plus or minus value. - Includes NIST-Traceable Calibration. - T-8071-0868 Probe to 1"-1MHz Single-Element Membrane Probe to measure Blow Holes in Thick PE Pipes and Fittings - Adjustable Gain in 5 steps (VLow, Low, Med, Hi & VHi) in 2db increments providing a 8 db gain adjust range (42–50 db). - 64 custom setups can be stored and retrieved for convenient use and labeled for easy identification - Display Hi/Lo Alarm Limits with audible and visual indicators. - 2 Year Warranty and CE-Certified - Metal housing provides strong protection against harsh environments. - Measures Coatings up to 0.100" |
- 산간벽지나 도서지방은 별도의 추가금액을 지불하셔야 하는 경우가 있습니다.
고객님께서 주문하신 상품은 입금 확인후 배송해 드립니다. 다만, 상품종류에 따라서 상품의 배송이 다소 지연될 수 있습니다.
교환 및 반품이 가능한 경우
- 상품을 공급 받으신 날로부터 7일이내 단, 가전제품의
경우 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.
- 공급받으신 상품 및 용역의 내용이 표시.광고 내용과
다르거나 다르게 이행된 경우에는 공급받은 날로부터 3월이내, 그사실을 알게 된 날로부터 30일이내
교환 및 반품이 불가능한 경우
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우. 단, 상품의 내용을 확인하기 위하여
포장 등을 훼손한 경우는 제외
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우
(예 : 가전제품, 식품, 음반 등, 단 액정화면이 부착된 노트북, LCD모니터, 디지털 카메라 등의 불량화소에
따른 반품/교환은 제조사 기준에 따릅니다.)
- 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우 단, 화장품등의 경우 시용제품을
제공한 경우에 한 합니다.
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 복제가 가능한 상품등의 포장을 훼손한 경우
(자세한 내용은 고객만족센터 1:1 E-MAIL상담을 이용해 주시기 바랍니다.)
※ 고객님의 마음이 바뀌어 교환, 반품을 하실 경우 상품반송 비용은 고객님께서 부담하셔야 합니다.
(색상 교환, 사이즈 교환 등 포함)